Specifications

Product Family

HPE M12 / M14 G2 Rack Rear Door Heat Exchanger, manufactured by Motivair (ChilledDoor technology)

Part Number Pattern

S4N00A through S4N20A and beyond — one SKU per rack-height / rack-width / voltage / feed-direction combination

42U 600 mm SKUs

S4N00A (M14, 208-230 V, bottom feed), S4N01A (M14, 260-290 V, top feed), S4N02A (M14, 260-290 V, bottom feed)

42U 800 mm SKUs

S4N03A (M12, 208-230 V, top), S4N04A (M14, 208-230 V, top), S4N05A (M12, 208-230 V, bottom), S4N06A (M14, 208-230 V, bottom), S4N07A (M14, 260-290 V, bottom)

48U 600 mm SKUs

S4N08A (M12, 208-230 V, top), S4N09A (M12, 208-230 V, bottom), S4N10A (M14, 208-230 V, top), S4N11A (M14, 208-230 V, bottom), S4N12A (M14, 260-290 V, bottom)

48U 800 mm SKUs

S4N17A (M12, 208-230 V, bottom), S4N18A (M12, 208-230 V, bottom), S4N19A and S4N20A (M14, 260-290 V variants)

Voltage Classes

208-230 V and 260-290 V input classes — selected per facility distribution standard

Feed Options

Top feed and bottom feed plumbing variants; choice is fixed by the rack row's overhead or underfloor pipe route

Rack Platforms

Fits HPE M12 and M14 G2 racks and HPE Cray XD / ARCS rack families

Accessories

Flowmeter upgrade kit (S4J44A), rear supply/return manifold kit (S6M05A), straight extension kit (S6K97A), CDU long secondary hose kit (S6K98A)

Cooling Role

Removes server exhaust heat at the rack rear door before it reaches the white space — room-neutral operation

Heat Removal

Motivair ChilledDoor technology is rated to remove 100 percent of the rack heat load, up to 75 kW per rack

Redundancy

Built-in failover and overcool operating modes with a PLC control and safety system

Monitoring

Monitors environmental variables continuously and adjusts cooling to conditions inside the data centre

Cabinet Integration

Also offered integrated into Panduit FlexFusion cabinets for a single-part-number rack plus cooling package

Rack Coverage

Standard models plus custom solutions; floor-mount and in-rack profiles; capacities scaling to multi-megawatt IT load

Overview

HPE sells rear door heat exchangers as fully part-numbered rack options under the S4N SKU family, built on Motivair's ChilledDoor technology. Because the SKU enumerates rack height, rack width, voltage class and feed direction, a rack row can be specified and ordered as rack plus cooling without an engineering submittal for each position.

The SKU layout is systematic: M12 and M14 denote the rack platform, 42U and 48U the height, 600 mm and 800 mm the width, 208-230 V and 260-290 V the input class, and top feed versus bottom feed the plumbing route. S4N01A is a 42U 600 mm M14 rack at 260-290 V with top feed; S4N11A is a 48U 600 mm M12 rack at 208-230 V with bottom feed.

The motive for specifying one is density. These units remove server exhaust heat at the rear door rather than letting it into the room, which is how a rack moves into the 20-75 kW range without a CRAH rebuild. Motivair's ChilledDoor design is rated for 100 percent heat removal up to 75 kW per rack, with built-in failover and overcool modes under PLC control. HPE also lists the matching plumbing accessories — flowmeter upgrade kit, supply/return manifold, extension and CDU hose kits — so the secondary loop can be specified in the same BOM.

Key Benefits

One SKU per rack/voltage/feed combination — no custom engineering submittal. 42U and 48U, 600 mm and 800 mm cover the common HPE rack fleet. Top or bottom feed matches the existing pipe route. Up to 75 kW per rack with 100 percent heat removal. PLC control with failover and overcool modes. Matching manifold and CDU accessories from the same catalogue.

Applications

HPE M12/M14 G2 rack fleets moving to liquid cooling; HPE Cray XD and ARCS AI clusters; colocation density upgrades; retrofits where overhead or underfloor pipe routes are already fixed; cabinets paired with Panduit FlexFusion.

Request a Quote — HPE M12 / M14 G2 REAR DOOR HEAT EXCHANGERS — S4N SKU FAMILY BY MOTIVAIR