Specifications
Product Family
Motivair MCDU coolant distribution units (4U in-rack and floor-mount) and the ChilledDoor rack cooling system
In-Rack Model
MCDU 4U — 102 kW rated capacity, 4U design mounted at the top or bottom of a standard 19″ rack enclosure
Floor-Mount Models
MCDU-15 at 310 kW, MCDU-25 at 625 kW, MCDU-40 at 1,250 kW, MCDU-50 at 1,725 kW and MCDU-60 at 2,350 kW
Sensible Cooling
100% sensible cooling up to 2.3 MW depending on model
Supply Water Temperature
Secondary loop supply temperatures from 55°F to 113°F+ (12.8°C to 45°C+), covering ASHRAE W1 through W5 classes
Heat Exchanger
Stainless steel plate heat exchanger separating the IT loop from facility water
Pumps
Redundant dual pumps with variable speed drives for reliable secondary loop circulation
Control Valve
Modulating 2-way valve that continuously adjusts CDU cooling capacity to IT demand
Dew Point Control
Maintains secondary loop water temperature above the data center dew point to eliminate condensation
Facility Water Source
Primary chilled water may come from a chiller, a cooling tower or a natural resource
Compatible IT Systems
Active and passive rear door heat exchangers plus direct-to-chip and on-chip liquid-cooled computer systems
ChilledDoor
Rear-door rack cooling system mounted to the back of a standard server rack, removing up to 75 kW per rack
Controls
Front-mounted PLC control system with adjustable water temperature set points, dew point control and alarm thresholds
Communication Protocols
BACnet MS/TP, BACnet IP, Modbus and LON for BMS integration and remote control
Monitoring
Records, trends and reports cooling system profiles for capacity and efficiency management
Redundancy
Inherent redundancy in pumps and control paths for maximum uptime
Application Classes
Ideal for W1-W5 cooling systems, from chilled-water rows to warm-water direct-to-chip loops
Custom Engineering
Custom OEM CDU designs for unique liquid cooling applications
Provenance
Motivair earned the distinction of cooling the world's first exascale computer systems; CDUs made in the USA
Overview
Motivair's MCDU family is a full ladder of coolant distribution units spanning a 4U in-rack model to a 2,350 kW floor-mount unit. The MCDU 4U fits at the top or bottom of a standard 19-inch rack at 102 kW, while the floor-mount line runs MCDU-15 at 310 kW, MCDU-25 at 625 kW, MCDU-40 at 1,250 kW, MCDU-50 at 1,725 kW and MCDU-60 at 2,350 kW — the same products that cooled the world's first exascale systems.
Each CDU performs five jobs: it decouples the IT cooling loop from facility water, controls coolant temperature and flow precisely, monitors and trends the loop, provides pump redundancy, and scales with server load in real time. A stainless steel plate heat exchanger transfers heat from the secondary loop to primary chilled water supplied by a chiller, cooling tower or natural source, while a modulating 2-way valve constantly matches cooling capacity to IT demand and a PLC holds the secondary loop above the room dew point to eliminate condensation.
For racks that need cooling without a full DLC loop, Motivair's ChilledDoor mounts directly to the rear of a standard server rack and removes up to 75 kW per rack, keeping a computing environment heat-neutral. Control and integration use BACnet MS/TP, BACnet IP, Modbus and LON, and Motivair builds custom OEM CDU designs for non-standard liquid cooling applications.
Key Benefits
One vendor from 102 kW to 2.35 MW: the same control architecture and redundancy model covers an in-rack 4U unit and a floor-mount megawatt unit, simplifying design, spares and BMS integration as density grows. W1-W5 warm water capability: supply temperatures from 55°F to 113°F+ let facilities run warm-water loops and cut chiller energy. Condensation-proof by control: dew point tracking keeps the secondary loop above room dew point, removing the condensation risk that limits how cold a DLC loop may run.
Applications
Direct-to-chip and on-chip liquid cooling in AI and HPC data centers, rear-door heat exchanger deployments in existing air-cooled racks, exascale and national-lab class installations, high-density colocation rows, and custom OEM liquid cooling loops.
Request a Quote — MOTIVAIR MCDU COOLANT DISTRIBUTION UNITS AND CHILLEDDOOR — 102 KW TO 2.35 MW, W1-W5 WARM WATER