Specifications

Product Family

Motivair MCDU coolant distribution units (4U in-rack and floor-mount) and the ChilledDoor rack cooling system

In-Rack Model

MCDU 4U — 102 kW rated capacity, 4U design mounted at the top or bottom of a standard 19″ rack enclosure

Floor-Mount Models

MCDU-15 at 310 kW, MCDU-25 at 625 kW, MCDU-40 at 1,250 kW, MCDU-50 at 1,725 kW and MCDU-60 at 2,350 kW

Sensible Cooling

100% sensible cooling up to 2.3 MW depending on model

Supply Water Temperature

Secondary loop supply temperatures from 55°F to 113°F+ (12.8°C to 45°C+), covering ASHRAE W1 through W5 classes

Heat Exchanger

Stainless steel plate heat exchanger separating the IT loop from facility water

Pumps

Redundant dual pumps with variable speed drives for reliable secondary loop circulation

Control Valve

Modulating 2-way valve that continuously adjusts CDU cooling capacity to IT demand

Dew Point Control

Maintains secondary loop water temperature above the data center dew point to eliminate condensation

Facility Water Source

Primary chilled water may come from a chiller, a cooling tower or a natural resource

Compatible IT Systems

Active and passive rear door heat exchangers plus direct-to-chip and on-chip liquid-cooled computer systems

ChilledDoor

Rear-door rack cooling system mounted to the back of a standard server rack, removing up to 75 kW per rack

Controls

Front-mounted PLC control system with adjustable water temperature set points, dew point control and alarm thresholds

Communication Protocols

BACnet MS/TP, BACnet IP, Modbus and LON for BMS integration and remote control

Monitoring

Records, trends and reports cooling system profiles for capacity and efficiency management

Redundancy

Inherent redundancy in pumps and control paths for maximum uptime

Application Classes

Ideal for W1-W5 cooling systems, from chilled-water rows to warm-water direct-to-chip loops

Custom Engineering

Custom OEM CDU designs for unique liquid cooling applications

Provenance

Motivair earned the distinction of cooling the world's first exascale computer systems; CDUs made in the USA

Overview

Motivair's MCDU family is a full ladder of coolant distribution units spanning a 4U in-rack model to a 2,350 kW floor-mount unit. The MCDU 4U fits at the top or bottom of a standard 19-inch rack at 102 kW, while the floor-mount line runs MCDU-15 at 310 kW, MCDU-25 at 625 kW, MCDU-40 at 1,250 kW, MCDU-50 at 1,725 kW and MCDU-60 at 2,350 kW — the same products that cooled the world's first exascale systems.

Each CDU performs five jobs: it decouples the IT cooling loop from facility water, controls coolant temperature and flow precisely, monitors and trends the loop, provides pump redundancy, and scales with server load in real time. A stainless steel plate heat exchanger transfers heat from the secondary loop to primary chilled water supplied by a chiller, cooling tower or natural source, while a modulating 2-way valve constantly matches cooling capacity to IT demand and a PLC holds the secondary loop above the room dew point to eliminate condensation.

For racks that need cooling without a full DLC loop, Motivair's ChilledDoor mounts directly to the rear of a standard server rack and removes up to 75 kW per rack, keeping a computing environment heat-neutral. Control and integration use BACnet MS/TP, BACnet IP, Modbus and LON, and Motivair builds custom OEM CDU designs for non-standard liquid cooling applications.

Key Benefits

One vendor from 102 kW to 2.35 MW: the same control architecture and redundancy model covers an in-rack 4U unit and a floor-mount megawatt unit, simplifying design, spares and BMS integration as density grows. W1-W5 warm water capability: supply temperatures from 55°F to 113°F+ let facilities run warm-water loops and cut chiller energy. Condensation-proof by control: dew point tracking keeps the secondary loop above room dew point, removing the condensation risk that limits how cold a DLC loop may run.

Applications

Direct-to-chip and on-chip liquid cooling in AI and HPC data centers, rear-door heat exchanger deployments in existing air-cooled racks, exascale and national-lab class installations, high-density colocation rows, and custom OEM liquid cooling loops.