Specifications

Product Family

Starline Track Busway (Legrand / Starline Power)

Construction

Extruded aluminium housing with roll-formed copper busbars in an open-channel design

Track Busway Rating

40 A to 1250 A

Series-S Track Busway

100 A to 1200 A with IP54 ingress protection for water, dust and contaminant exposure

High Power Busway

Up to 6300 A in enclosed systems with ingress protection up to IP65

Ingress Protection

IP2X / IP3X on standard Track Busway; IP54 on Series-S; up to IP65 on High Power Busway

Standard

UL857 listed

Plug-In Units

Tap-off boxes insert at any point along the open channel with integrated circuit protection

No-Downtime Changes

Plug-in units can be added or removed without shutting down the busway

Maintenance

Torque-free joints require no field maintenance

Field Proven

Manufactured to the same design for more than 30 years

Installation

No new wiring or cable whips needed to add, relocate or remove a power drop

Compact Tiers

T3 (100 A to 225 A) and T5 (250 A to 1250 A) Track Busway sections

High-Density Tiers

RCP IP68 and XCP-HP / XCP-S enclosed busway from 630 A to 6300 A

Tap-Off Options

Fiberglass and metal tap-off boxes with region-specific plug-in configurations

Power Monitoring

End feed, plug, retrofit and standalone metering options, plus a remote plug-in actuator

Typical Applications

Data centers, mission critical facilities, manufacturing plants and commercial buildings

Overview

Overhead busway is a different way of distributing rack power. Instead of home-running cable and whip to every cabinet, a busway is a prefabricated extruded aluminium housing carrying rolled copper busbars with a continuous access slot along its length. Plug-in units (tap-off boxes) are inserted into that slot wherever power is needed.

The operational consequence is that rack power becomes reconfigurable. Adding, relocating or removing a power drop no longer requires an electrician to pull new cable and a maintenance window to terminate it: the plug-in unit carries its own integrated circuit protection and is inserted without de-energising the busway. In an AI hall where rack layouts change between GPU generations, that is the difference between a week of electrical work and a shift of re-plugging.

Starline's range covers the whole density spectrum. Standard Track Busway runs 40 A to 1250 A at IP2X/IP3X; Series-S adds IP54 sealing from 100 A to 1200 A for harsher environments; High Power Busway reaches 6300 A at up to IP65. The T3 (100–225 A) and T5 (250–1250 A) sections cover typical rack rows, while the enclosed RCP IP68 and XCP-HP/XCP-S systems handle 630 A to 6300 A at row and room level. End feed, plug, retrofit and standalone metering options bring the same busway into the power-monitoring framework.

Key Benefits

Reconfigurable rack power with no downtime — plug-in units with integrated circuit protection are added or removed at any point along a live busway. 40 A to 6300 A of coverage, IP2X to IP65 sealing, UL857 listing and torque-free joints that need no field maintenance.

Applications

AI data halls where rack layouts change between GPU generations, mission critical facilities requiring no-downtime power changes, retrofit metering of existing overhead power, manufacturing and commercial buildings, and any row where cable-and-whip power distribution cannot keep pace with rack turnover.

Request a Quote — STARLINE TRACK BUSWAY — OVERHEAD PLUG-IN POWER DISTRIBUTION FOR AI DATA CENTERS

QS Compute — global B2B supply of AI computing hardware, edge AI systems and accelerators. Volume pricing, 15-day sample lead time.

Get Your Quote →

Related Products

Raritan PX4 Intelligent Rack PDU Server Technology PRO4X Rack PDU Vertiv PowerDirect 5000 800VDC Schneider Electric Galaxy VXL UPS