Specifications
Product Family
Server Technology PRO4X rack PDU (Legrand Data Center Solutions)
PDU Families
Switched POPS, Smart POPS, Switched and Smart (POPS = Per Outlet Power Sensing)
Management Controllers
iX12 and iX9 hot-swappable controllers, 100% field-replaceable
iX12 Controller
ARM Cortex A53 800 MHz (TI AM623), 512 MB DDR4 RAM, 32 MB QSPI NOR flash
iX9 Controller
ARM Cortex A5 500 MHz (Atmel SAMA5D21), 256 MB DDR3 RAM, 32 MB SPI NOR flash
Input Voltage
100 V, 120 V, 200 V, 208 V, 230 V, 240 V, 400 V and 415 V
Input Current
16 A to 100 A, single-phase and three-phase
Outlet Count
Up to 54 outlets per PDU, mixing HDOT Cx and HDOT C13
HDOT Cx Technology
Patented outlet design removes unnecessary mouldings; outlets are more than 20% smaller than standard PDU outlets
Outlet Density
One pair of PRO4X PDUs with evenly distributed HDOT outlets replaces configurations that previously required three or four PDUs
Form Factor
Zero U vertical
Local Display
320 x 240 backlit colour TFT with auto-flip orientation; shows voltage, current or active power per line, breaker or outlet
Networking
2 x 10/100/1000 Gigabit Ethernet, 2 x USB-A, 1 x USB-B, sensor port and PDU Link port
Cascading / Linking
Cascade up to 32 PDUs per Ethernet port (16 via USB bridging); PDU Linking supports up to 8 PDUs with redundant controller power
Environmental Sensors
Plug-and-play sensor bus for up to 32 sensor functions or 12 sensor packages across temperature, humidity, airflow, differential air pressure, water/leak, dust, contact closures, proximity/motion and vibration
Metering Accuracy
Billing-grade ±0.5% metering compliant with IEC 61557-12 (PMD-III)
Power Quality Metrics
kW, kVA, V, A, voltage and current harmonic distortion, true and displacement power factor, voltage dip/swell, neutral current/voltage, current inrush and crest factor
Management Protocols
SNMP v2/v3, HTTP(S), SSH CLI, Telnet, SMTP, IPv6/IPv4, MODBUS/TCP, Redfish RESTful API and JSON-RPC
Security
Configurable inbound/outbound firewall, granular user and user-group permissions, enforced password policy, third-party VAPT tested
Certifications
FCC Part 15 Class A, TUVus and cTUV, IEC 62368, CE and UKCA
Overview
The PRO4X is Server Technology's flagship Zero-U intelligent rack PDU, and its reason to exist is outlet density. The patented HDOT outlet design strips away the mouldings a conventional C13 or C19 outlet needs, making each outlet more than 20% smaller. The practical result, in Server Technology's own framing, is that a pair of PRO4X PDUs with HDOT outlets can serve a rack that would previously have needed three or four PDUs.
That density is paired with billing-grade metering. The PRO4X samples AC coherently and meters to ±0.5%, compliant with IEC 61557-12 PMD-III, reporting kW, kVA, V, A, harmonic distortion, true and displacement power factor, voltage dip and swell, neutral current, inrush and crest factor. For a colocation tenant or an internal chargeback model, that is the difference between an estimate and an invoice line.
The controllers are hot-swappable — 100% field-replaceable with finger-safe, screwless replacement — and support cascading 32 PDUs behind one Ethernet port, PDU Linking for redundant controller power, and up to 32 environmental sensor functions. Input coverage runs from 100 V single-phase to 415 V three-phase at 16 A to 100 A, so the same platform serves an edge cabinet and a 415 V AI row.
Key Benefits
Up to 54 HDOT Cx outlets per Zero-U PDU — more than 20% smaller outlets that replace three or four PDUs with two. Billing-grade ±0.5% metering to IEC 61557-12, hot-swappable iX12/iX9 controllers, and 32-PDU cascading behind a single Ethernet port. Input coverage spans 100–415 V at 16–100 A.
Applications
High-density AI and GPU racks where outlet count is the binding constraint, colocation and multi-tenant racks requiring billable circuit metering, hyperscale rows with cascaded PDUs, racks needing granular environmental and leak monitoring, and remote power cycling of unstaffed edge cabinets.