Specifications
Product Line
Vertiv Geist UPDU (Universal Power Distribution Unit)
Universal Input
One PDU accepts worldwide AC power: 16 A to 63 A at 120 V to 415 V
Phase Support
Single-phase and three-phase input configurations
Detachable Cord
The input cord is a separate item and detaches from the PDU, so one SKU covers multiple site power standards
Power Capacity
11 kW and 22 kW maximum power load models
Form Factors
Vertical (0U) and horizontal rack mounting
Receptacle Options
Multiple C13 / C19 combination layouts plus region-specific outlet types
Monitoring Options
Basic, metered and monitored variants
Switching Options
Unit-level and outlet-level switched variants for remote power cycling
Outlet Temperature Rating
60 °C rated outlets and cord set
Locking Outlets
U-Lock C13 / C19 receptacles prevent accidental disconnection of production equipment
Three-Phase Density
415 V three-phase inputs supported, enabling 17.2 kW+ per rack PDU
Management
Remote monitoring and outlet control over the network with DCIM integration
Deployment Model
Standardise a single PDU part number across regions and vary only the input cord
Overview
The Vertiv Geist UPDU exists to solve a procurement problem rather than a power problem. A conventional rack PDU is a region-specific part: a 208 V 30 A L6-30P unit is useless in a 400 V three-phase European hall. The UPDU decouples the PDU from its input: the unit accepts 16 A to 63 A at 120 V to 415 V, and the input cord is a separate, detachable component.
That means a single PDU part number can be stocked and deployed across regions, with only the cord changing. For AI and HPC racks where a single 3-phase 415 V feed may carry 17.2 kW or more, the 22 kW UPDU models cover the highest-density single-rack deployments in the range.
The UPDU is available in vertical (0U) and horizontal form factors with C13/C19 combination outlets, U-Lock locking receptacles rated to 60 °C, and basic, metered, monitored and switched options, so the same platform serves a cabinet of network switches and a cabinet of eight-way GPU servers.
Key Benefits
One part number worldwide with a field-swappable detachable cord, 11 kW and 22 kW capacity in 0U, and U-Lock locking outlets rated to 60 °C. It removes the regional SKU sprawl that otherwise dominates rack-PDU spares planning.
Applications
Multi-region data centre rollouts, AI and HPC racks fed at 415 V three-phase, colocation cages where the tenant's input standard is not known in advance, and edge sites that must run on whatever power is available locally.
Request a Quote — VERTIV GEIST UPDU — UNIVERSAL RACK PDU WITH DETACHABLE INPUT CORD