Specifications

Product Family

Eaton Pow-R-Way III (enclosed feeder) and PowerWave 2 (open-channel plug-in, formerly PDI)

Pow-R-Way III Rating

Up to 5,000 A copper / 4,000 A aluminium

Voltage Class

600 V low-voltage busway

Housing

Two-piece all-aluminium enclosure derived from utility-grade bus duct design

Tap-Off Outlets

Finger-safe plug-in outlets along the run for in-service tap-off units

Short-Circuit Withstand

Highest 6-cycle short-circuit withstand rating in its class

PowerWave 2 Rating

100 A to 4,000 A open-channel plug-in busway

PowerWave 2 Metering

Integrated Power Xpert energy meter with revenue-grade accuracy and real-time branch circuit monitoring

Coupling

CouplerTek integral coupling minimises keep-out zones

Reconfiguration

Tap-off units added or repositioned without de-energising the busway run

Enclosure Options

Indoor rated, plus outdoor tap boxes with gasketed access covers front and back

Seismic

Seismic-certified configurations available for high-risk regions

Standards

UL 857 and CSA C22.2 No. 43

Installation

Factory-built bolt-together sections; BIM-friendly Revit models available

Design Resources

Eaton Pow-R-Way III design guide DG017002EN and technical data TD01701001E

Density Support

Engineered for AI halls with rack densities above 40 kW and overhead distribution above aisles

MAC Efficiency

Open-channel design supports moves, adds and changes without an electrician or planned outage

Overview

Busway has replaced cable and conduit in AI data halls because it installs in hours rather than days and can be reconfigured in service. Eaton's two families cover the two architectural roles: Pow-R-Way III is the enclosed feeder busway that carries power from switchgear to the hall, rated to 5,000 A copper, while PowerWave 2 is the open-channel plug-in busway that runs above the racks and accepts tap-off units wherever a new cabinet appears.

For GPU deployments the decisive advantage is reconfigurability. When a hall adds a dozen high-density AI racks, tap-off units are bolted onto the existing run without de-energising it, and PowerWave 2's integrated Power Xpert meter provides revenue-grade branch circuit monitoring so the new load is visible immediately. Pow-R-Way III brings seismic-certified, aluminium-housed feeder construction for the upstream run.

Key Benefits

In-service tap-offs let AI halls grow rack by rack without a planned outage. Revenue-grade branch metering in PowerWave 2 gives operators per-circuit power visibility. Aluminium housing and seismic certification reduce structural load and satisfy high-risk-region codes, and bolt-together factory sections cut installed labour versus conduit.

Applications

Overhead distribution in AI and GPU data halls, hyperscale and colocation risers and feeder runs, retrofit of existing halls with new high-density racks, and any facility that must add power capacity without shutting down live compute.