Specifications
Product Family
APC Symmetra LX modular redundant UPS, 208 V / 240 V
Power Range
4 kVA to 16 kVA, scalable in 4 kVA increments without replacing the chassis
Topology
Double-conversion online, true sine wave output
Redundancy
N+1 redundant, hot-swappable power modules and battery modules
Tower Models
SYA4K8P (4 kVA to 8 kVA), SYA8K8P (8 kVA to 8 kVA), SYA8K16P (8 kVA to 16 kVA), SYA12K16P (12 kVA to 16 kVA), SYA16K16P (16 kVA to 16 kVA)
Rack-Mount Models
SYA8K8RMP, SYA8K16RMP, SYA12K16RMP, SYA16K16RMP
Extended-Run Tower
SYA8K16PXR, SYA12K16PXR, SYA16K16PXR with external battery cabinets
Power Modules
SYPM2KU (2 kVA) and SYPM4KU / SYPM4KP / SYPM4KI (4 kVA) — field-replaceable
Output at 16 kVA
12.8 kW; 17.1 minutes backup at half load (6,400 W), 5.1 minutes at full load (12,800 W)
Compact Tower Chassis
4-8 kVA tower: 671 mm height, 157.7 kg, 2,762 BTU/hr heat rejection
Management
Integrated network manageability with real-time UPS health and environmental condition reporting
Battery Modules
Hot-swappable battery modules; user-replaceable without load shutdown
Bypass
Internal maintenance bypass path for module service while the load stays energised
Typical Load
Server rooms, network closets, edge AI racks, and lab compute needing per-increment growth
Input
208 V / 240 V single-phase (SYA family)
Service Model
Modules are the service unit — no whole-UPS swap, no rack rebuild to add capacity
Overview
Symmetra LX is a chassis you buy once and grow into. Power capacity arrives as 2 kVA and 4 kVA power modules (SYPM2KU, SYPM4KU) that slide into the same frame, so a 4 kVA SYA4K8P can become a 16 kVA SYA16K16P without a rip-and-replace.
Redundancy is the point of the design. Because power and battery modules are hot-swappable and configured N+1, a failed module is pulled and replaced while the critical load stays on line. That matters for AI and edge racks where the compute node in question has a single inlet and cannot tolerate a transfer.
The family splits cleanly into tower chassis (SYA4K8P through SYA16K16P), rack-mount chassis (SYA8K8RMP through SYA16K16RMP), and extended-run tower models (SYA8K16PXR and up) that accept external battery cabinets for longer runtime at full load.
Key Benefits
Scale in 4 kVA increments in a single chassis. N+1 hot-swap power and battery modules cut service downtime to a module swap. Double-conversion online output isolates the load from sags, surges and frequency drift. Real-time network health reporting. Tower, rack-mount and extended-run variants from one modular platform.
Applications
Server rooms and network closets with staged growth; edge AI inference racks; test and measurement labs; small data centres needing N+1 without a full modular-UPS budget; retrofit runtime expansion via external battery cabinets.