Specifications

Product Family

APC Symmetra LX modular redundant UPS, 208 V / 240 V

Power Range

4 kVA to 16 kVA, scalable in 4 kVA increments without replacing the chassis

Topology

Double-conversion online, true sine wave output

Redundancy

N+1 redundant, hot-swappable power modules and battery modules

Tower Models

SYA4K8P (4 kVA to 8 kVA), SYA8K8P (8 kVA to 8 kVA), SYA8K16P (8 kVA to 16 kVA), SYA12K16P (12 kVA to 16 kVA), SYA16K16P (16 kVA to 16 kVA)

Rack-Mount Models

SYA8K8RMP, SYA8K16RMP, SYA12K16RMP, SYA16K16RMP

Extended-Run Tower

SYA8K16PXR, SYA12K16PXR, SYA16K16PXR with external battery cabinets

Power Modules

SYPM2KU (2 kVA) and SYPM4KU / SYPM4KP / SYPM4KI (4 kVA) — field-replaceable

Output at 16 kVA

12.8 kW; 17.1 minutes backup at half load (6,400 W), 5.1 minutes at full load (12,800 W)

Compact Tower Chassis

4-8 kVA tower: 671 mm height, 157.7 kg, 2,762 BTU/hr heat rejection

Management

Integrated network manageability with real-time UPS health and environmental condition reporting

Battery Modules

Hot-swappable battery modules; user-replaceable without load shutdown

Bypass

Internal maintenance bypass path for module service while the load stays energised

Typical Load

Server rooms, network closets, edge AI racks, and lab compute needing per-increment growth

Input

208 V / 240 V single-phase (SYA family)

Service Model

Modules are the service unit — no whole-UPS swap, no rack rebuild to add capacity

Overview

Symmetra LX is a chassis you buy once and grow into. Power capacity arrives as 2 kVA and 4 kVA power modules (SYPM2KU, SYPM4KU) that slide into the same frame, so a 4 kVA SYA4K8P can become a 16 kVA SYA16K16P without a rip-and-replace.

Redundancy is the point of the design. Because power and battery modules are hot-swappable and configured N+1, a failed module is pulled and replaced while the critical load stays on line. That matters for AI and edge racks where the compute node in question has a single inlet and cannot tolerate a transfer.

The family splits cleanly into tower chassis (SYA4K8P through SYA16K16P), rack-mount chassis (SYA8K8RMP through SYA16K16RMP), and extended-run tower models (SYA8K16PXR and up) that accept external battery cabinets for longer runtime at full load.

Key Benefits

Scale in 4 kVA increments in a single chassis. N+1 hot-swap power and battery modules cut service downtime to a module swap. Double-conversion online output isolates the load from sags, surges and frequency drift. Real-time network health reporting. Tower, rack-mount and extended-run variants from one modular platform.

Applications

Server rooms and network closets with staged growth; edge AI inference racks; test and measurement labs; small data centres needing N+1 without a full modular-UPS budget; retrofit runtime expansion via external battery cabinets.

Request a Quote — APC SYMMETRA LX MODULAR UPS — 4 TO 16 KVA N+1 SCALABLE

QS Compute — global B2B supply of AI computing hardware, edge AI systems and accelerators. Volume pricing, 15-day sample lead time.

Get Your Quote →