Specifications

Product

ROL4000-48U65 in-row coolant distribution unit (CDU)

Type

Liquid-to-liquid (L2L), facility water to technology cooling system (TCS)

Cooling Capacity

2 MW (2,000 kW)

Approach Temperature

3 °C

Available Pressure

Up to 80 PSI for cold plate loops, control valves and manifolds

Form Factor

48U in-row

Architecture

Redundant pump design with standby bypass loop

Control

Dynamic condensation-free control; automatic coolant replenishing

Leak Management

Automatic leak detection with integrated monitoring

Application

Next-generation AI processors and high-density GPU racks

Facility Interface

Designed to reduce facility cooling load by raising supply temperatures

Typical Rack Density

Targets 100 kW+ per rack AI deployments

Vendor

Eaton Boyd Thermal (Boyd Corporation)

Service

Commissioning, in-region design collaboration and long-term maintenance

Also In Family

RAA32-10U2 10U L2A (32 kW) and RAA22-10U19 rack CDUs

Overview

The Eaton Boyd ROL4000-48U65 is an in-row, liquid-to-liquid coolant distribution unit rated at 2 MW of cooling capacity with a 3 °C approach temperature. It was developed specifically for next-generation technology cooling system (TCS) loops, delivering up to 80 PSI of available pressure to drive flow through high-performance cold plate loops, control valves and rack manifolds.

By operating at a narrow approach temperature the unit raises the return water temperature seen by the facility plant, which reduces or eliminates the need for facility chillers and lowers overall power usage effectiveness. Redundant pumps, a standby bypass loop, automatic coolant replenishing and automatic leak detection address the availability requirements of AI training clusters.

Boyd (now part of Eaton) supplies the full cooling ecosystem around the CDU: cold plates, rack manifolds, liquid loops, leak detectors, tubing and quick disconnects. The ROL4000 sits above the RAA32-10U2 10U liquid-to-air unit (32 kW) for sites without facility water.

Key Benefits

2 MW per unit for rack densities beyond 100 kW. 3 °C approach temperature reduces facility cooling load. 80 PSI available pressure for dense cold plate loops. Redundant pumps and bypass loop for continuous operation.

Applications

AI training and inference halls, hyperscale GPU clusters, colocation high-density halls, retrofits of air-cooled data centres to direct liquid cooling, and TCS loop deployments at 100 kW+ per rack.