Specifications
Product family
Delta GoCool coolant distribution units (CDU)
LTA CDU GoCool-80
80 kW liquid-to-air coolant distribution unit
LTA CDU GoCool-150
150 kW liquid-to-air coolant distribution unit
LTA CDU GoCool-260
260 kW liquid-to-air coolant distribution unit
LTL CDU GoCool-660
660 kW liquid-to-liquid coolant distribution unit
LTL CDU GoCool-1000
1,000 kW (1 MW) liquid-to-liquid CDU
LTL CDU GoCool-1200
1,200 kW liquid-to-liquid CDU
LTL CDU GoCool-1500
1,500 kW liquid-to-liquid CDU
LTL CDU GoCool-3000
3,000 kW (3 MW) liquid-to-liquid CDU
Cooling architecture
Liquid-to-air (LTA) and liquid-to-liquid (LTL) configurations
RDHx CoolDoor
Rear-door heat exchanger, 30 kW to 50 kW per door
RowCool DX, R Series
Direct-expansion row cooler, 30 kW to 45 kW
RowCool CW
Chilled-water row cooler for in-row heat capture
RoomCool CW, L Series
Chilled-water room cooling for the surrounding hall
Two-phase immersion
Two-phase immersion cooling systems for extreme-density racks
Loop integration
Facility-water and technology-cooling loop separation at the CDU
Deployment
Rack-level, row-level and room-level configurations
Primary use case
Liquid cooling for AI training and inference rack densities
Overview
The Delta GoCool series is a complete coolant distribution unit family for liquid-cooled AI datacentres. It spans three liquid-to-air models at 80 kW, 150 kW and 260 kW for retrofits and edge rooms, and five liquid-to-liquid models from 660 kW through 1,000 kW, 1,200 kW and 1,500 kW up to the 3,000 kW (3 MW) GoCool-3000 for hyperscale deployment.
A CDU separates the facility water loop from the technology cooling loop, delivering filtered, temperature-controlled coolant to cold plates and racks. Delta's liquid-to-liquid units handle the high heat loads of GPU-dense AI racks, while the liquid-to-air variants reject heat directly to room air where a facility water loop is unavailable.
The GoCool family is complemented by the CoolDoor rear-door heat exchanger at 30-50 kW per door, RowCool direct-expansion and chilled-water row coolers, RoomCool chilled-water hall cooling and two-phase immersion systems. Together they cover rack-level, row-level and room-level heat rejection for AI clusters.
Key Benefits
Full power range. 80 kW to 3,000 kW across one CDU family. Loop separation. Hydraulic isolation between facility water and technology cooling loops. Retrofit-friendly. Liquid-to-air models avoid the need for facility water. Hyperscale-ready. The 3 MW GoCool-3000 supports the densest AI racks. Complete ecosystem. RDHx, row coolers, room coolers and immersion from one supplier.
Applications
AI and HPC datacentre liquid cooling, GPU rack heat rejection, retrofit of air-cooled halls to liquid, edge data rooms, high-density inference clusters, two-phase immersion deployment.
Request a Quote — DELTA GOCOOL CDU SERIES — 80 KW TO 3,000 KW LIQUID-TO-AIR AND LIQUID-TO-LIQUID COOLANT DISTRIBUTION UNITS