Specifications

Model

CSU2400AP (family also covers CSU1800AP, CSU2000AP)

Output Power

2400 W

Output Voltage

12 V main + 12 V standby

Efficiency

80 PLUS Titanium (94 %+ peak for the CSU family)

Input Voltage

90-264 V AC (wide range)

Form Factor

CRPS common redundant power supply

Redundancy

N+1 / N+N hot-swap

Bus Protocol

PMBus 1.2 with analogue sense

iTHD

Low total harmonic current distortion at light load (EN61000-3-2)

Control

Remote set-up, monitoring and control via Artesyn universal PMBus GUI

Hot Swap

Yes — blind-mate CRPS connector

Protection

OV, UV, OC, SC, OT protection with data logging

Certifications

IEC 62368 CB, UL/CSA, UKCA, DEMKO, CQC, EAC, KC (EMC)

Documentation

CSU1800-2400 W datasheet, technical reference notes, 3D models

Manufacturer

Advanced Energy (Artesyn Embedded Power brand)

Application Class

Enterprise compute, cloud, hyperscale, networking, storage

Compatibility

Industry-standard CRPS bay, drop-in with CSU1600AT / CSU1800AP

Lifecycle

Active production

Overview

The Advanced Energy (Artesyn) CSU2400AP is a 2400 W common redundant power supply — CRPS — targeting enterprise and hyperscale servers, storage arrays and network chassis that need high output in a standard 1U-or-2U CRPS bay. It is part of the CSU family that spans 550 W to 2400 W in a common form, fit and function, which is what lets an OEM qualify one mechanical and thermal design and then fit different wattages per SKU.

Electrically it delivers a 12 V main rail plus 12 V standby across a 90-264 V AC input, certified to 80 PLUS Titanium with peak efficiency in the 94 %+ band for the family. That efficiency tier matters in a dense rack: at 2400 W per module, the difference between Platinum and Titanium is roughly 100 W of waste heat per supply, which is heat the CDU has to remove. Low iTHD at light load keeps the site power factor clean during the low-utilisation periods that dominate real fleets.

Control and telemetry run over PMBus 1.2, so the host BMC can read input power, output current per rail, temperature and fan status, and can set output limits and sequencing remotely through Artesyn's PMBus GUI. Protection covers over-voltage, under-voltage, over-current, short-circuit and over-temperature with data logging — useful when a fleet-level failure has to be root-caused. Hot-swap N+1 or N+N redundancy with the blind-mate CRPS connector means a failed module is replaced without taking the chassis down.

Key Benefits

2400 W in the industry-standard CRPS envelope for the highest-power single-bay server designs. 80 PLUS Titanium efficiency cuts rack-level waste heat and CDU load. PMBus 1.2 telemetry gives per-rail current, temperature and fault logging to the BMC. Hot-swap N+1 / N+N keeps the chassis up through a module failure. Fault logging on OV/UV/OC/SC/OT supports fleet root-cause analysis. One mechanical design across 550 W-2400 W reduces qualification cost.

Applications

AI and GPU server chassis power bays; enterprise rack servers and dense compute sleds; storage arrays and JBOD enclosures; top-of-rack and spine network chassis; hyperscale OCP-style racks with CRPS bays; telecom and edge data center cabinets; retrofit programmes replacing lower-wattage CRPS modules.

Request a Quote — ADVANCED ENERGY CSU2400AP — 2400 W CRPS TITANIUM SERVER POWER SUPPLY

QS Compute — global B2B supply of AI computing hardware, edge AI systems and accelerators. Volume pricing, 15-day sample lead time.

Get Your Quote →

Related Products

Artesyn CSU2000AP — 2000 W CRPS Power Supply Delta DPS-3000AB — 3000 W Server Power Supply Murata D1U54P-3000 — 3000 W Front-End PSU